Volume 2, Issue 4 (Autumn 2013 2013)                   Arch Hyg Sci 2013, 2(4): 127-134 | Back to browse issues page

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Rezaei Kalantari R, Yari A R, Ahmadi E, Azari A, Tahmasbi Zade M, Gharagazlo F. Survey of corrosion and scaling potential in drinking water resources of the villages in Qom province by use of four stability indexes (With Quantitative and qualitative analysis. Arch Hyg Sci 2013; 2 (4) :127-134
URL: http://jhygiene.muq.ac.ir/article-1-18-en.html
1- PhD. Assistant Professor, Department of Environmental Health Engineering, Iran University of Medical Sciences, Tehran, Iran
2- Resarch center for environmental pollutants, Qom university of medical sciences, Qom, Iran
3- M.Sc Student, Department of Environmental Health Engineering, Tehran University of Medical Sciences, Tehran, Iran
4- Student’s Scientific Research Center, Tehran University of Medical Sciences, Tehran, Iran
5- Tehran University of Medical Sciences
Abstract:   (5106 Views)

Background & Aims of the Study:  Corrosion and scaling are the most common problems of water facilities. Corrosion imposes many financial and health loss on system and consumer respectively, scaling also causes clogging and head loss in network. The purpose of this study is to determine the corrosion and scaling potential of water supply sources of Qom villages. Materials & Methods This cross-sectional study was done in 12 months (from 2011-2012). 100 samples were collected to determine pH, total dissolved solids (TDS), temperature, alkalinity, Calcium hardness and residual chlorine, and water corrosion and scaling have been studied by using Langelier, Ryzner, aggressive and Puckorius indexes. Results:  The results illustrate that Qom village water according to the Langelier index equals 1.62 (±0.11), according to Rayzner index equals 10.5 (±0.17), based on Aggressive index equals 12.035 (±0.14) and based on Pokurious index equals 9.92 (±0.13) respectively. Comparison of four index’s were showed that Water conditions in all villages of Qom is in corrosive range. Conclusions:  According to this study, water supply in Qom village is corrosive, one of the effective ways for solves this problem is pH adjustment by lime

Full-Text [PDF 408 kb]   (1390 Downloads) |   |   Full-Text (HTML)  (616 Views)  
Type of Study: Original Article | Subject: General
Received: 2016/02/13 | Accepted: 2016/02/23 | Published: 2016/02/23

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2025 CC BY-NC 4.0 | Archives of Hygiene Sciences

Designed & Developed by : Yektaweb